OEM Part Number Cross References:
Compatibility:
Manufacturer | Model |
Draeger | Narkomed 4 |
MEK | MP 1000, MP 700 |
Welch Allyn | 53000, 5300P, 530T0, 530TP, 53N00, 53N0P, 53NT0, 53NTP, 53S00, 53S0P, 53ST0, 53STP, Propaq Encore |
Cleaning the equipment:
To clean the sensor and its connecting cable, follow these steps:
Use warm soapy water: Clean the sensor and cable by gently washing them with warm, soapy water. Ensure that the water is not too hot, and use a mild soap or detergent.
Use a soft cloth with soapy water or 70% isopropyl alcohol: Moisten a soft cloth with either soapy water or 70% isopropyl alcohol. Gently wipe the probe and cable with the cloth, taking care not to damage the surface of the visual indicator and the detector.
Avoid abrasive agents or chemical products: Do not use any abrasive agents or chemical products except for 70% isopropyl alcohol. These can potentially damage the sensor and its components.
Dry the probe and cable thoroughly: After cleaning, allow the probe and cable to dry completely before using them again. Ensure that there is no moisture remaining, as this can affect the proper functioning of the equipment.
Avoid irradiation, autoclaving, soaking, or immersing the probe: Do not subject the probe to irradiation, autoclaving, soaking, or immersion in any type of solution. These actions can damage the probe and compromise its performance.
Keep the probe clean and dry: It is important to maintain the cleanliness and dryness of the probe during use. Regularly check for any signs of contamination or damage and clean as necessary.
Average life expectancy: The average life expectancy of a SpO2 sensor is typically more than a year when used under the conditions recommended in the operating instructions. Following the proper cleaning and maintenance guidelines can help prolong the lifespan of the sensor.
Equipment: * Connect the sensor cable to the appropriate device (pulse oximeter) * Turn on the device and check correct operation by consulting the monitor's operating instructions. *To ensure proper operation of the monitor, please connect and disconnect the sensor cable from the monitor cable. Use correctly and safely
The sensor and its connecting cable require system inspection at least once or more per month, depending on frequency of use and sanitization of the cable *Visual inspection (appearance of insulator, connector contact pins, etc.) *Verification of mechanical integrity of the connector Do not use and discard any sensor with mechanical or electrical defects. The operating conditions of the SpO2 sensor and its cable are as follows: *Ambient temperature: 0° to +40° C
*Relative humidity: 0 to 80%
*Atmospheric pressure: 860 to 1060 HPa For use of SpO2 sensors and their connecting cables in departments where compliance with sterility levels is required, Med Accessories recommends the following cleaning, disinfection or sterilization methods: