Compatible with Mindray, Datascope NIBP air hose blood pressure nibp, MS15-15 Adult/Pediatric Single Hose
Manufacturer | OEM Part # |
---|---|
AMC | HO-S15158-10 |
Advanced Instrumentations | 01.59.036104 |
American Diagnostic Corporation (ADC) | 9005BPC |
Contec | 2.3.11.00007 |
Criticare | 705, CAT-706 |
Draeger | 2606218 |
Edan | M13-36036, 01.59.036118-11 (3 m) |
Invivo | E2810-06 |
M | 25302 (3 m) |
Mindray > Datascope | 200683-04-0003, 200683-04-0004, 509B-30-06259, 0683-00-0189-80, 0683-04-0003 (5 ft (1.8 meters)), 0683-04-0004 (10 ft) |
HP | M3918A, 989803136931 |
Sage | H04-15-15 |
Spacelabs | 714-0060-00 (12 ft), 714-0061-00, 714-0018-00 |
Sunnex | 15-100-0026 |
Manufacturer | Model |
---|---|
American Diagnostic Corporation (ADC) | ADView 2 |
Aspen | Iradimed, V1 |
Biolight | M6, M69, M7000, M800 Handheld, M8000, M8500, M9000, M9500 |
Bionet | BMP300 |
Contec | CMS 5100, CMS 6000, CMS 7000, CMS 8000, CMS 9000 |
Criticare | 506 series, 506N3, 506NT3, 507, 507EL, 507EL/C, 507ELC2, 507MPS, 507NJC, 8100 series, nCompass, nGenuity |
DRE | Waveline EZ MAX |
Datex Ohmeda | enGuard CM5 |
Edan | M3, M3A, M3B, M50, M8, M80, M8A, M8B, M9, M9A, iM50, iM60, iM60GT, iM70, iM8A, iM8B, iM9, iM9A |
Invivo | MDE Escort Prism |
Mediana | V10 |
Medica D | Logicare Series 2000 |
Mindray > Datascope | Accutorr Plus, Accutorr V, DPM3, DPM4, DPM5, Duo, MEC 1200, PM 8000, PM 8000 Express, PM 9000 Express, Passport 2, Passport 2LT, Passport V, Spectrum, Spectrum OR, T5, Trio, V-Series, V12, V21, XG |
Spacelabs | 90369, 91393 Xprezzon, 91496, Ultraview SL, Ultraview SL 2400, Ultraview SL 2700 |
Sunnex | M8000A |
Warranty/Liability Information:
Med Accessories warrants its sensors against defects in materials and/or workmanship for one year from the date of purchase. This warranty covers any problems caused by manufacturing defects. However, it does not cover damage or breakage caused by abuse or neglect of the sensor.
Med Accessories warrants that its equipment meets the specifications of applicable current safety and performance standards.
Additionally, the following warnings should be heeded:
Sensors designed for specific displays: Sensors are designed specifically to work with certain displays. It is the operator's responsibility to ensure compatibility between monitors, probes and cables before using them together. Use of incompatible components may result in reduced accuracy and performance.
Accuracy evaluation: It is not recommended to use functional testers or blood oxygen simulators to evaluate sensor accuracy. Instead, refer to the instruction manual of the device and related accessories for appropriate accuracy assessment methods.
Consult operating instructions: Always consult the operating instructions for the equipment and related accessories before operating the equipment. This will help ensure compatibility and correct usage.
Interference from Portable/Mobile RF Communications Equipment: Remember that portable and mobile RF communications equipment may affect the operation of the equipment. Take necessary precautions to minimize disruption.
Disposal Compliance: When disposing of the sensor, follow local regulations regarding proper disposal methods.