Compatible M 1269 LNOP neonate wrap spo2 sensor
OEM Part Number Cross References:
Manufacturer | OEM Part # |
---|---|
9315 | |
1269 (LNOP DCI), 1560 (LNOP DC-195) (No cord) | |
HP | |
P10-11M | |
Compatibility:
Manufacturer | Model |
---|---|
CareFusion > Alaris | 8220 |
Draeger | Infinity Delta, Infinity Delta XL, Infinity Gamma, Infinity Gamma XL, Infinity Kappa, Infinity M540, Narkomed 6400 |
GE Healthcare > Corometrics | 250cx |
GE Healthcare > Critikon > Dinamap | ProCare 100, ProCare 200, ProCare 300, ProCare 400, ProCare Ausculatory 400 |
Invivo | M8 |
M | Rad-5 |
Mennen | Horizon XVu |
Mindray > Datascope | Accutorr Plus, Accutorr V, DPM4, Duo, PM 6000, PM 7000, PM 8000, PM 9000, Passport 2, Passport 2LT, Passport V, Spectrum, Spectrum OR, Trio, V12, V21, VS 800 |
HP | SureSigns VM1 |
Spacelabs | Ultraview SL, Ultraview SL 2400, Ultraview SL 2700 |
Stryker > Medtronic > Physio Control | Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E |
Welch Allyn | 45NE0-E1 LX, Propaq CS, Spot Vital Signs 42MOB, Spot Vital Signs 42MTB-E1 |
Zoll | E Series, M Series, R Series |
Company Profile
Med Accessories SpO2 sensors are designed for continuous, non-invasive monitoring of arterial oxygen saturation and pulse rate. They are fully compatible replacement sensors for use with major brands of pulse oximeters.
Med Accessories offers reusable sensors for four patient categories:
Adults: These sensors are suitable for patients weighing more than 30 kg.
Children: Designed for patients weighing 10-50 kg.
Infant: Suitable for patients weighing 3-20 kg.
Neonate/Adult: These sensors are suitable for patients weighing less than 3 kg or greater than 40 kg.
It is important to select the appropriate sensor model that matches your specific pulse oximeter specifications. Med Accessories ensures that its SpO2 sensors are designed to meet original equipment manufacturer (OEM) requirements.
By choosing the correct Med Accessories sensor model for your pulse oximeter, you can ensure compatibility and accurately monitor arterial oxygen saturation and pulse rate.
Remind
Compatibility: Make sure the SpO2 sensor connector is compatible with the patient monitor socket. Different patient monitors may have different types of connectors, such as 5-pin or 6-pin connectors. Verify that the sensor connector mates with the receptacle on the specific patient monitor.
Patient Terminal Type: Determines whether the SpO2 sensor requires a snap-on or clip-on patient terminal. Some sensors have snap-on connectors that attach easily to the patient's fingers or earlobes, while others use clip-on connectors that clamp securely to the patient's fingers. Choose the appropriate terminal type based on your preferences and patient comfort.
Patient Population: Verify that the SpO2 sensor is appropriate for the target patient population. Sensors are designed for different age groups such as adults or newborns. Make sure the sensor you choose is designed for the age group of patients you are monitoring.