Add to Cart
Manufacturer | OEM Part # |
---|---|
GE Healthcare > Marquette | 2016560-001, 700657-001, E9001YT |
Pacific Medical | NEGE9001 |
Sage | V02-13M |
Compatibility:
Manufacturer | Model |
---|---|
GE Healthcare > Marquette | CAM 14, CASE, MAC 5000, MAC 5500 |
Nstallation/Utilization/Maintenance:
To ensure proper installation, utilization, and maintenance of Med Accessories sensors and their connecting cables, please follow the instructions below:
Patient:
Place the SpO2 sensor on the patient at the appropriate measurement site.
Application:
Before each use, clean the sensor and its cable.
Place the sensor on the index finger, ensuring that the finger is fully inserted and the tip of the finger rests against the finger stop inside the sensor.
Alternatively, you can use small-sized thumb, middle and ring fingers, as well as the little finger or the big toe as measurement sites.
Make sure the fingernail is located under the finger stop on the SpO2 sensor clamp.
Avoid placing the sensor on the same arm as the blood pressure cuff, arterial catheter, or intravascular line.
Remove all nail polish as it can affect accuracy.
Do not use the sensor inside or near an MRI.
Avoid having intense light sources near the sensor.
For long-term use, change the measurement site every 4 hours to maintain the integrity of the patient's skin.
In the case of restless patients or excessive motion, use Med Accessories Soft tip, wrap, or multi-site sensor to help secure the sensor to the patient.
Maintenance:
Regularly inspect the sensor and its cable for any signs of wear or damage. If any damage is detected, discontinue use and replace with a new sensor.
Clean the sensor and cable before each use according to the recommended cleaning instructions provided by Med Accessories.
Store the sensors in a clean and dry environment, following the storage guidelines provided by Med Accessories.
Follow any additional maintenance instructions provided by Med Accessories specific to the sensors you are using.
By following these installation, utilization, and maintenance guidelines, you can ensure the proper functioning, accuracy, and longevity of Med Accessories sensors, as well as the safety and comfort of the patients being monitored.
Here are some additional types of SpO2 sensors:
Adult finger clip SpO2 sensor: Designed for adults weighing over 40kg. It is applied to the index finger or other fingers for measurement.
Pediatric finger clip SpO2 sensor: Intended for pediatric patients weighing between 10kg and 40kg. It is applied to the index finger or other fingers for measurement.
Adult silicone SpO2 sensor: Suitable for adults weighing over 40kg. It is applied to the index finger or other fingers for measurement.
Pediatric silicone SpO2 sensor: Designed for pediatric patients weighing between 10kg and 40kg. It is applied to the index finger or other fingers for measurement.
Infant silicone wrap SpO2 sensor: Suitable for neonates weighing 1-4kg, infants weighing 3-15kg, and pediatric patients weighing over 10kg. It is applied to the pediatric index or other fingers, neonate's foot, or infant's great toe for measurement.
Adult ear clip SpO2 sensor: Specifically designed for adults weighing over 40kg. It is applied to the ear for measurement. Please note that this sensor should only be used with a pulse oximeter that has autoconditioning power function.
Animal SpO2 sensor: Intended for use with dogs and cats. It can be applied to the ear or tongue for measurement. Please note that this sensor should only be used with an animal pulse oximeter or a pulse oximeter that has autoconditioning power function.
Disposable SpO2 Sensor: Available for both adults and infants. These sensors are designed for single-use and are disposable after each use.